Heavy duty installation system
Thermo Proof
Product information "Thermo Proof"
Properties
- Heavy-duty distance installation for ETICS, clinker or on flat roofs
- Stainless steel prevents unattractive spots of rust
- Approved by building authorities
- Practically no energy loss
- Quick and easy installation
- Infinitely adjustable Iso-Spacer insulation sleeve
- For insulation up to 300 mm
Description and field of application
Thermo Proof is a heavy-duty distance installation system for heat insulated façades (ETICS) comprising:
- Iso-Spacer with large support surface and SW 24 drive for improved transfer of force
- Steel parts made from A4 quality stainless steel; M12 thread; length 400 mm
- Static mixer extension for deep drill holes
Processing and assembly
- Drill through heat installation
- Measure out heat installation
- Make a drill hole in the building material and remove a layer of plaster if required
- Clean the drill hole
- Shorten the threaded rod if required (length = drill hole depth + layer of insulation + fixture + 20 mm) and Iso-Spacer
- In perforated brick, only with perforated sleeve. Place this fully in the drill hole
- Fill the drill hole in the substrate up to 2/3 full with injection mortar or fill the perforated sleeve fully
- Insert the threaded rod with pre-installed Iso-Spacer into the drill hole by turning it slightly
- Screw on the Iso-Spacer until just before the plaster
- Allow the injection mortar to harden
- Seal the gap with silicone
- Install the fixture
Area of application: | Indoors and outdoors |
---|---|
Eigenschaft: | Montagesystem |
Insulation thickness: | 300 |
Safety instructions
- The partial safety factors of the assessments and a partial safety factor γF = 1.4 of the impact are to be considered in the holding values
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- 1 Not included in approvals Z-21.8-2011
- 2 Applies to the drill hole depth in the building material. The thickness of the insulation and plaster layer are still to be added
- 3 The entire approval notice Z-21.8-2011 and the approvals ETA-09/0258, ETA-13/0052 and ETA-13/0053 + ETA-13/0047, ETA-17/0501, ETA-17/0503 listed therein must be observed when sizing
ETA European (Technical Approvals)
Thermo_Proof_Z-21.8-2011_DE_20190930.pdfTOXLeistungserklaerung
AQUA_STOP_1213-80050_DE_(22.12.2017).pdfTOXSicherheitsdatenblattDeutschland
Aqua Stop_741402_S_de_de.pdf
Product information "Thermo Proof"
Properties
- Heavy-duty distance installation for ETICS, clinker or on flat roofs
- Stainless steel prevents unattractive spots of rust
- Approved by building authorities
- Practically no energy loss
- Quick and easy installation
- Infinitely adjustable Iso-Spacer insulation sleeve
- For insulation up to 300 mm
Description and field of application
Thermo Proof is a heavy-duty distance installation system for heat insulated façades (ETICS) comprising:
- Iso-Spacer with large support surface and SW 24 drive for improved transfer of force
- Steel parts made from A4 quality stainless steel; M12 thread; length 400 mm
- Static mixer extension for deep drill holes
Processing and assembly
- Drill through heat installation
- Measure out heat installation
- Make a drill hole in the building material and remove a layer of plaster if required
- Clean the drill hole
- Shorten the threaded rod if required (length = drill hole depth + layer of insulation + fixture + 20 mm) and Iso-Spacer
- In perforated brick, only with perforated sleeve. Place this fully in the drill hole
- Fill the drill hole in the substrate up to 2/3 full with injection mortar or fill the perforated sleeve fully
- Insert the threaded rod with pre-installed Iso-Spacer into the drill hole by turning it slightly
- Screw on the Iso-Spacer until just before the plaster
- Allow the injection mortar to harden
- Seal the gap with silicone
- Install the fixture
Area of application: | Indoors and outdoors |
---|---|
Eigenschaft: | Montagesystem |
Insulation thickness: | 300 |
Safety instructions
- The partial safety factors of the assessments and a partial safety factor γF = 1.4 of the impact are to be considered in the holding values
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- 1 Not included in approvals Z-21.8-2011
- 2 Applies to the drill hole depth in the building material. The thickness of the insulation and plaster layer are still to be added
- 3 The entire approval notice Z-21.8-2011 and the approvals ETA-09/0258, ETA-13/0052 and ETA-13/0053 + ETA-13/0047, ETA-17/0501, ETA-17/0503 listed therein must be observed when sizing