Spaced mounting system
Thermo Proof Mini
Product information "Thermo Proof Mini"
Properties
- Specifically for soft insulation materials such as rock wool
- For insulation thicknesses from 50-120mm
- Variable connection options (M10 external thread, M6 internal thread or screws with Ø 3-5mm)
- No thermal bridges
- No pressure load on the façade
- Slim head geometry for invisible fixings
Description and field of application
- The Thermo Proof Mini is a distance installation system for light to medium loads for fixing, for example, downpipes, signs, blind guides, mailboxes etc.
- Secure anchoring in building material with Barracuda 14/70
- The pre-assembled Thermo Proof Mini is easily screwed in with TX25
- When used with M10 installation threaded pin: fixing of e.g. downpipes
- When used without installation pin: fixing of mailboxes, outdoor cameras
- When used without installation threaded pin and Barracuda 5/25: fixing of attachments with screws Ø 3.0 - 5.0 e.g. motion sensors, house numbers
Processing and assembly
- Shorten threaded rod to length required
- Drill a Ø14mm hole in the building material (drill hole depth 90mm + tWDVS)
- Clean the drill hole
- Screw Barracuda 14/70 onto the threaded rod with max. two turns
- Hammer the pre-assembled Thermo Proof Mini into the drill hole until the black Iso Spacer is flush with the outer wall.
- Screw in completely until the collar of the Iso Spacer is flush with the plaster
Application example 1: rainwater downpipe fixing - Attach the TOX Flexi Cap and install the pipe bracket Application example 2: installation with M6 screw for various uses
- 7. Unscrew the installation threaded pin
- 8. Fixing the attachment with M6 screw
Application example 3: installation with screws for various uses - 7. Unscrew the installation threaded pin
- 8. Hammer Barracuda 5/25 into the Iso Spacer
- 9. Fixing of the attachment with a Ø 3.0 - 5.0 screw
Area of application: | Indoors and outdoors |
---|---|
Diameter: | 14 |
Eigenschaft: | Montagesystem |
Insulation thickness: | 120 |
Screw type: | metric screw |
Suitable screw diameter: | M6, chipboard screws 3 - 5mm |
Safety instructions
- The anchoring depth of the wall plug must be observed
- Drilling method and drill hole cleaning must be adapted to the building material
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- * The max. tensile load when used with Barracuda 5/25 in the Iso-Spacer is limited to 35 kg
- ** Applies to insulation materials with plaster thicknesses ≥ 5m
Product information "Thermo Proof Mini"
Properties
- Specifically for soft insulation materials such as rock wool
- For insulation thicknesses from 50-120mm
- Variable connection options (M10 external thread, M6 internal thread or screws with Ø 3-5mm)
- No thermal bridges
- No pressure load on the façade
- Slim head geometry for invisible fixings
Description and field of application
- The Thermo Proof Mini is a distance installation system for light to medium loads for fixing, for example, downpipes, signs, blind guides, mailboxes etc.
- Secure anchoring in building material with Barracuda 14/70
- The pre-assembled Thermo Proof Mini is easily screwed in with TX25
- When used with M10 installation threaded pin: fixing of e.g. downpipes
- When used without installation pin: fixing of mailboxes, outdoor cameras
- When used without installation threaded pin and Barracuda 5/25: fixing of attachments with screws Ø 3.0 - 5.0 e.g. motion sensors, house numbers
Processing and assembly
- Shorten threaded rod to length required
- Drill a Ø14mm hole in the building material (drill hole depth 90mm + tWDVS)
- Clean the drill hole
- Screw Barracuda 14/70 onto the threaded rod with max. two turns
- Hammer the pre-assembled Thermo Proof Mini into the drill hole until the black Iso Spacer is flush with the outer wall.
- Screw in completely until the collar of the Iso Spacer is flush with the plaster
Application example 1: rainwater downpipe fixing - Attach the TOX Flexi Cap and install the pipe bracket Application example 2: installation with M6 screw for various uses
- 7. Unscrew the installation threaded pin
- 8. Fixing the attachment with M6 screw
Application example 3: installation with screws for various uses - 7. Unscrew the installation threaded pin
- 8. Hammer Barracuda 5/25 into the Iso Spacer
- 9. Fixing of the attachment with a Ø 3.0 - 5.0 screw
Area of application: | Indoors and outdoors |
---|---|
Diameter: | 14 |
Eigenschaft: | Montagesystem |
Insulation thickness: | 120 |
Screw type: | metric screw |
Suitable screw diameter: | M6, chipboard screws 3 - 5mm |
Safety instructions
- The anchoring depth of the wall plug must be observed
- Drilling method and drill hole cleaning must be adapted to the building material
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- * The max. tensile load when used with Barracuda 5/25 in the Iso-Spacer is limited to 35 kg
- ** Applies to insulation materials with plaster thicknesses ≥ 5m