frame plug
Fassad XL
Whether you are a DIY enthusiast or a professional craftsman: the TOX Fassad XL frame plug is suitable for building authority-approved fixings in numerous building materials - even for particularly heavy facades thanks to its high bending moment!
Whether in concrete, solid brick, perforated brick or aerated concrete, the Fassad XL frame plug offers optimum force distribution thanks to its double expansion and fixes facades and roof substructures securely in the building material. The special SW17 screw supplied has a TX50 internal drive and the molded washer ensures optimum force transmission. The plug is also equipped with an anti-rotation lock for safe and convenient installations (as a push-through installation).
The Fassad XL 14 x 220 mm frame plug incl. special screw SW17 is supplied in a handy cardboard box containing 25 pieces.
The red all-purpose plug has made TOX famous: the company is a leader in the field of all-purpose plugs. The comprehensive assortment is consistently geared towards the needs of customers and end users. The TOX brand stands for innovative products and competent solutions in the field of fastening technology.
| Anchoring depth: | 70 |
|---|---|
| Approval number: | ETA-17/1002 |
| Area of application: | Indoors and outdoors |
| Clearance hole diameter: | 14,5 |
| Diameter: | 14 |
| Diameter of included screw: | 10 |
| Drill diameter: | 14 |
| Drill hole depth: | 85 |
| Length of included screw: | 230 |
| Plug dimension: | 14 x 220 |
| Property: | Rahmendübel |
| Beton C20/25 | 300 Kg |
|---|---|
| Hochlochziegel ≥ Hlz12 Rohdichte 1 kg/dm³ | 40* Kg |
| Porenbeton ≥ PB2, PP2 | 40* Kg |
| Porenbeton ≥ PB4, PP4 | 80* Kg |
| Porenbeton ≥ PB6, PP6 | 140* Kg |
| Mauerziegel Mz 20 | 130 Kg |
Safety instructions
- When sizing, the entire declaration of performance of the Fassad XL must be observed
- The partial safety factors of the resistances and a partial safety factor of γF = 1.4 are to be considered
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- For other masonry types see approval ETA-17/1002
- * Not included in ETA-17/1002
TOXZulassungDeutsch
Fassad_XL_ETA_17-1002_DE_20220804.pdfLeistungserklärung
Fassad_XL_0432-CPR-0250_DE_04012021.pdfWhether you are a DIY enthusiast or a professional craftsman: the TOX Fassad XL frame plug is suitable for building authority-approved fixings in numerous building materials - even for particularly heavy facades thanks to its high bending moment!
Whether in concrete, solid brick, perforated brick or aerated concrete, the Fassad XL frame plug offers optimum force distribution thanks to its double expansion and fixes facades and roof substructures securely in the building material. The special SW17 screw supplied has a TX50 internal drive and the molded washer ensures optimum force transmission. The plug is also equipped with an anti-rotation lock for safe and convenient installations (as a push-through installation).
The Fassad XL 14 x 220 mm frame plug incl. special screw SW17 is supplied in a handy cardboard box containing 25 pieces.
The red all-purpose plug has made TOX famous: the company is a leader in the field of all-purpose plugs. The comprehensive assortment is consistently geared towards the needs of customers and end users. The TOX brand stands for innovative products and competent solutions in the field of fastening technology.
| Anchoring depth: | 70 |
|---|---|
| Approval number: | ETA-17/1002 |
| Area of application: | Indoors and outdoors |
| Clearance hole diameter: | 14,5 |
| Diameter: | 14 |
| Diameter of included screw: | 10 |
| Drill diameter: | 14 |
| Drill hole depth: | 85 |
| Length of included screw: | 230 |
| Plug dimension: | 14 x 220 |
| Property: | Rahmendübel |
| Beton C20/25 | 300 Kg |
|---|---|
| Hochlochziegel ≥ Hlz12 Rohdichte 1 kg/dm³ | 40* Kg |
| Porenbeton ≥ PB2, PP2 | 40* Kg |
| Porenbeton ≥ PB4, PP4 | 80* Kg |
| Porenbeton ≥ PB6, PP6 | 140* Kg |
| Mauerziegel Mz 20 | 130 Kg |
Safety instructions
- When sizing, the entire declaration of performance of the Fassad XL must be observed
- The partial safety factors of the resistances and a partial safety factor of γF = 1.4 are to be considered
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- For other masonry types see approval ETA-17/1002
- * Not included in ETA-17/1002