Shield anchors (Hornbach)
Hac
Whether you are a DIY enthusiast or a professional craftsman: the HAC shield anchor offers reliable installations in concrete and solid brick with a dense structure. The heavy-duty anchor is suitable for temporary and permanent fixings, e.g. for water boilers, rim holders, pull-up bars etc.. The standard screws and threaded rods can be loosened and tightened without having to remove the plug.
The heavy-duty shield anchor offers a stable and sophisticated design and is not only equipped with a robust anchor sleeve made of zinc-plated steel, but also with four integrated expansion wings that provide an extra-strong hold. The shield anchor is suitable for pre-positioned installation and can also be easily removed again for high flexibility in use. No additional setting tool is required for installation.
The Hac M8 x 55 mm shield anchor is supplied in a handy cardboard box containing 50 pcs., ensuring that everything is neatly stowed away, safely transportable and quickly to hand.
The red all-purpose plug has made TOX famous: the company is a leader in the field of all-purpose plugs. The comprehensive assortment is consistently geared towards the needs of customers and end users. The TOX brand stands for innovative products and competent solutions in the field of fastening technology.
| Anchoring depth: | 50 |
|---|---|
| Area of application: | Indoors |
| Clearance hole diameter: | 9 |
| Diameter: | M8 |
| Drill diameter: | 14 |
| Drill hole depth: | 55 |
| Plug dimension: | M8 x 55 |
| Property: | Maschinendübel, Maschinendübel (Hornbach) |
| Suitable screw diameter: | M8 |
| Tightening torque: | 25 |
| Gerissener Beton C20/25 | 430 Kg |
|---|---|
| Ungerissener Beton C20/25 | 840 Kg |
Safety instructions
- The anchoring depth of the wall plug must be observed
- Drilling method and drill hole cleaning must be adapted to the building material
- The recommended loads only apply to installation in the building material, not for installation in joints
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- *only for solid masonry with dense structure / holding values depend on building material
Whether you are a DIY enthusiast or a professional craftsman: the HAC shield anchor offers reliable installations in concrete and solid brick with a dense structure. The heavy-duty anchor is suitable for temporary and permanent fixings, e.g. for water boilers, rim holders, pull-up bars etc.. The standard screws and threaded rods can be loosened and tightened without having to remove the plug.
The heavy-duty shield anchor offers a stable and sophisticated design and is not only equipped with a robust anchor sleeve made of zinc-plated steel, but also with four integrated expansion wings that provide an extra-strong hold. The shield anchor is suitable for pre-positioned installation and can also be easily removed again for high flexibility in use. No additional setting tool is required for installation.
The Hac M8 x 55 mm shield anchor is supplied in a handy cardboard box containing 50 pcs., ensuring that everything is neatly stowed away, safely transportable and quickly to hand.
The red all-purpose plug has made TOX famous: the company is a leader in the field of all-purpose plugs. The comprehensive assortment is consistently geared towards the needs of customers and end users. The TOX brand stands for innovative products and competent solutions in the field of fastening technology.
| Anchoring depth: | 50 |
|---|---|
| Area of application: | Indoors |
| Clearance hole diameter: | 9 |
| Diameter: | M8 |
| Drill diameter: | 14 |
| Drill hole depth: | 55 |
| Plug dimension: | M8 x 55 |
| Property: | Maschinendübel, Maschinendübel (Hornbach) |
| Suitable screw diameter: | M8 |
| Tightening torque: | 25 |
| Gerissener Beton C20/25 | 430 Kg |
|---|---|
| Ungerissener Beton C20/25 | 840 Kg |
Safety instructions
- The anchoring depth of the wall plug must be observed
- Drilling method and drill hole cleaning must be adapted to the building material
- The recommended loads only apply to installation in the building material, not for installation in joints
- Approved wall plugs must be used for fixings where safety is of importance (see also www.tox.de/safety+loads)
- *only for solid masonry with dense structure / holding values depend on building material